2N from solaredge in NTC co-location centre

To ensure continuous A and B power in the NTC co-location centre, SolarEdge B300 UPSs are used.
NTC streker lyseblå

MORE THINGS

NTC is expanding
NTC is generally expanding within everything data center related. AI has led to a need for expansion of resources and we are now 22 in total, distributed at addresses where there is a need for on-site service and support.
Welcome Thomas Rovik
NTC Services AS(NTC) is very pleased to announce that Thomas Rovik has chosen to be employed by us. NTC is experiencing significant growth in the data center business, which requires us to scale up and add resources to help us achieve our future growth goals.
Welcome Tor Erlend Rubach
NTC Services AS(NTC) is very pleased to announce that Tor Erlend Rubach has chosen to be employed by us. NTC is experiencing significant growth in the data center business, which requires us to scale up and add resources to help us achieve our future growth goals.
Welcome Marius Ohrvik Olsen
NTC Services AS(NTC) is very pleased to announce that Marius Ohrvik Olsen has chosen to be employed by us. NTC is experiencing great growth in the data center business, which requires us to scale up and add resources to help us achieve our future growth goals.
Welcome Kjell Ove Tenold
NTC Services AS(NTC) is very pleased to announce that Kjell Ove Tenold has joined our team. NTC is experiencing significant growth in the data center business, which requires us to scale up and add resources to help us achieve our future growth goals.
cirkla solaredge Oslo broadcast GMBH

NTC customers expect continuous power 24/7/365 in the co-location center in Billingstadsletta 17. Front window city power supplemented by a generator in cases of power outages on the delivery side, we provide A and B power from 2 pcs 300kVA SolarEgde B300 machines. These have a scalable and redundant structure on all critical components, so that in the service context we will never have downtime and, if necessary, can hot-swap components if the need arises. Each of the UPS is supplied with battery power from independent FIAMM front-mounted VRLA batteries. To also have full control over charging, voltage levels and other battery properties in operation, we use a BACS monitoring system from Generex. This solution also ensures a longer lifespan for the battery installation so that we can expect a lifespan of between 10 and 15 years for these before replacement. We have spare capacity in the data centre, approx. 35 rack spaces if anyone needs to make use of the external placement of servers, networks and storage in a center with a high level of service, including associated services. Contact us on: 66 75 86 46

Solaredge

https://www.solaredge.com/us/products/ups 

https://www.generex.de/

CONTACT US

We design, sell, deliver, install, operate and provide service for your data centre. If you are interested in our services or wish to collaborate on business opportunities in the Norwegian market, please contact us!

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.