DATA CENTER-
SERVICES
DATA CENTER SERVICES
FLEXIBLE
NTC rents out the market’s most flexible data center spaces/racks.
CUSTOMIZED
CERTAINLY
NTC supplies the safest level (2N) of power and cooling to colocation customers.
FLEKSIBEL
NTC leier ut markedets mest fleksible datasenterplasser/rack.
KUNDETILPASSET
NTC leverer kundetilpassede tjenester til leietakere av datasenterplass.
SIKKERT
NTC leverer sikreste nivå(2N) av strøm og kjøling til colocation kunder.
This is NTC’s offer for server operation in optimized areas for companies that already have or will make the necessary investments in IT equipment, but which do not have the option of good enough physical security of the facility in terms of power and cooling.
COLOCATION
Colocation
We deliver server operation for companies that already have or will make the necessary investments in IT equipment.
NTC has extensive experience in building Norway's most energy-efficient data centres
Today we can get below 1.1 in PUE with Rear Door Heat Exchangers, Direct Water Cooling or Immersion Cooling. There is no longer a practical upper limit on the actual load in the computer racks, today we have solutions that handle up to 200kW per rack, if the project has hardware that requires that type of capacity, such as in connection with High Performance Computing (HPC). In our self-built colocation centre, we currently have a PUE of 1.19.
NTC supplies complete turnkey data centers
NTC builds complete, turnkey data centers. We mainly deliver to the SME market and up to a few Mega Watt total loads in the projects. We build either in a modular design in a container or prefabricated format, or into existing buildings. The latter has the advantage that you then get a much lower consumption of steel and concrete, which has a very favorable impact on the projects’ CO2 accounts.
Several of our customers have also largely checked out and used the market on the second-hand market for racks, PDUs and other equipment which not only provides a favorable entry cost in the project, but also contributes strongly to the circular economy.
WHY CHOOSE NORWAY?
Climate, an average temperature year over year is 6 degrees Celsius, this makes cooling a lot easier and more environment friendly. In the winter, minus 20 degrees Celsius is common. This improves the PUE and makes the data center more sustainable.
Sustainability, 98 percent of the energy produced in Norway is renewable, the normal energy mix is a little lower, due to some export and import, but Norway is the country with the highest share of renewable energy in the world. 100% Renewable energy can be arranged.
Economy, energy prices in Norway has historically been very low compared to the rest of Europe, and they still are. This can make a significant difference.
Stability. Norway has been a country with political stability, even if governments change, the differences is not great. Being a part of NATO, and situated in a quiet part of Europe, Norway is considered a safe country.
FREQUENTLY ASKED QUESTIONS
We preferably sell whole racks, but feel free to ask us, we always have some free space for customers who need less than this.
It will depend on how many kilowatts of load will be installed into the rack. It will determine the price that contains the following:
- 2 power strips for A and B power, 2 x 16Amp 1-phase = 3,680W load redundant
- 2 power strips for A and B power, 2 x 32Amp 1-phase = 7,360W load redundant
- 2 power strips for A and B power, 2 x 16Amp 3-phase = 11kW load redundant
- 2 power strips for A and B power, 2 x 32Amp 3-phase = 22kW load redundant
- In special cases, the customer wants 2 x A + 2 x B supply, we have racks that are adapted to that need.
- All the power rails are minimum managed, i.e. we can centrally read the rack’s loads and possibly identify bias loads.
- 1pc rack, either 42U high, 60cm wide, 120cm deep, or 42U high, 80cm wide, 120cm deep.
- 1pc Fiber A and 1pc Fiber B up to the rack, other needs are priced and installed in addition by NTC.
- Power supply from A and B UPS, supplied with power from a unit that starts automatically in the event of a power failure.
- Fire extinguishing included.
- Access control included.
- 24/7 monitoring included.
- Separation from other customers as required.
- Access for customers who receive an access card.